H05RR-F Cable

  • High flexibility, durability
  • Rated at 300/500V
  • Insulated with EPR, providing excellent protection against moisture, oil, chemicals, and abrasion
  • Suitable for a wide range of indoor and outdoor applications, including powering portable tools, household appliances, etc

H05RR-F cable is a harmonized, flexible rubber-insulated cable, designed to endure light mechanical stress while maintaining optimal electrical conductivity. It is rated at 300/500V and can be operated well at the temperature between -35℃ and 60℃. Its cross sectional conductor sizes are available in 0.75mm², 1mm²,1.5mm²,2.5mm². The H05RR-F cable features a sturdy construction with bare or tinned stranded copper conductors meticulously insulated with EPR, sheathed with CPE, which ensures excellent insulation properties and resilience against environmental factors.

The HO5RR-F cable is appropriate for indoor use in both dry and damp conditions and can also be temporarily employed outdoors. It is often utilized to connect a range of household devices, including office and kitchen appliances. However, it is not intended for industrial, commercial, or agricultural purposes.

Certification SAA, VDE, or UCIEE
Operating temperature -35℃+60℃
Rated voltage 300V/500V
Conductor Bare or tinned stranded copper conductor
Insulation material EPR
Sheath material CPE

H05RR-F Cable Construction

(VDE Certificated, Approval according to DIN EN 50525-2-21 )
No of cores x nominal cross sectional area Copper wire number x diameter Insulation thickness Insulation on  diam (mm) Sheath thickness (mm) Completed Diam(mm) Max conductor resistance(Ω/km)
The average The minimum The average The minimum
2×0.75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.8 0.58 6.4±0.20 26
2×1.0mm² 32X0.20mm 0.6 0.44 2.6±0.05 0.9 0.67 7.0±0.20 19.5
2×2.5mm² 48X0.20mm 0.8 0.62 3.3±0.05 1.0 0.75 8.4±0.20 13.3
3G0,75mm² 49X0.254mm 0.9 0.71 3.95±0.05 1.1 0.84 10.2±0.20 7.98
3G0,75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.9 0.67 7.0±0.20 26
3G0,75mm² 32X0.20mm 0.6 0.44 2.6±0.05 0.9 0.67 7.3±0.20 19.5
3G 1.5mm² 48X0.20mm 0.8 0.62 3.3±0.05 1.0 0.75 9.0±0.20 13.3
3G 2.5mm² 49X0.254mm 0.9 0.71 3.95±0.05 1.1 0.84 11.0±0.20 7.98
4G0.75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.9 0.67 7.8±0.20 26
4G 1.0mm² 32X0.20mm 0.6 0.44 2.6±0.05 0.9 0.67 8.3±0.20 19.5
4G 1.5mm² 48X0.20mm 0.8 0.62 3.3±0.05 1.1 0.84 0.4±0.20 13.3
4G 2.5mm² 49X0.254mm 0.9 0.71 3.95±0.05 1.2 0.92 12.3±0.20 7.98
(SAA Certificated, approval according to AS/NZS 60245.4   or UCIEE Certificated, approval according to IEC 60245.4)
No of cores x nominal cross sectional area Copper wire number x diameter Insulation thickness Insulation on  diam (mm) Sheath thickness (mm) Completed Diam(mm) Max conductor resistance(Ω/km)
The average The minimum The average The minimum
2×0.75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.8 0.58 6.4±0.20 26
2×1.0mm² 32X0.20mm 0.6 0.44 2.6±0.05 0.9 0.67 7.0±0.20 19.5
2×2.5mm² 48X0.20mm 0.8 0.62 3.3±0.05 1.0 0.75 8.4±0.20 13.3
3G0,75mm² 49X0.254mm 0.9 0.71 3.95±0.05 1.1 0.84 10.2±0.20 7.98
3G0,75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.9 0.67 7.0±0.20 26
3G0,75mm² 32X0.20mm 0.6 0.44 2.6±0.05 0.9 0.67 7.3±0.20 19.5