H05RR-F Cable
- High flexibility, durability
- Rated at 300/500V
- Insulated with EPR, providing excellent protection against moisture, oil, chemicals, and abrasion
- Suitable for a wide range of indoor and outdoor applications, including powering portable tools, household appliances, etc
H05RR-F cable is a harmonized, flexible rubber-insulated cable, designed to endure light mechanical stress while maintaining optimal electrical conductivity. It is rated at 300/500V and can be operated well at the temperature between -35℃ and 60℃. Its cross sectional conductor sizes are available in 0.75mm², 1mm²,1.5mm²,2.5mm². The H05RR-F cable features a sturdy construction with bare or tinned stranded copper conductors meticulously insulated with EPR, sheathed with CPE, which ensures excellent insulation properties and resilience against environmental factors.
The HO5RR-F cable is appropriate for indoor use in both dry and damp conditions and can also be temporarily employed outdoors. It is often utilized to connect a range of household devices, including office and kitchen appliances. However, it is not intended for industrial, commercial, or agricultural purposes.
| Certification | SAA, VDE, or UCIEE |
| Operating temperature | -35℃+60℃ |
| Rated voltage | 300V/500V |
| Conductor | Bare or tinned stranded copper conductor |
| Insulation material | EPR |
| Sheath material | CPE |
H05RR-F Cable Construction
(VDE Certificated, Approval according to DIN EN 50525-2-21 )
| No of cores x nominal cross sectional area | Copper wire number x diameter | Insulation thickness | Insulation on diam (mm) | Sheath thickness (mm) | Completed Diam(mm) | Max conductor resistance(Ω/km) | ||
| The average | The minimum | The average | The minimum | |||||
| 2×0.75mm² | 24X0.20mm | 0.6 | 0.44 | 2.4±0.05 | 0.8 | 0.58 | 6.4±0.20 | 26 |
| 2×1.0mm² | 32X0.20mm | 0.6 | 0.44 | 2.6±0.05 | 0.9 | 0.67 | 7.0±0.20 | 19.5 |
| 2×2.5mm² | 48X0.20mm | 0.8 | 0.62 | 3.3±0.05 | 1.0 | 0.75 | 8.4±0.20 | 13.3 |
| 3G0,75mm² | 49X0.254mm | 0.9 | 0.71 | 3.95±0.05 | 1.1 | 0.84 | 10.2±0.20 | 7.98 |
| 3G0,75mm² | 24X0.20mm | 0.6 | 0.44 | 2.4±0.05 | 0.9 | 0.67 | 7.0±0.20 | 26 |
| 3G0,75mm² | 32X0.20mm | 0.6 | 0.44 | 2.6±0.05 | 0.9 | 0.67 | 7.3±0.20 | 19.5 |
| 3G 1.5mm² | 48X0.20mm | 0.8 | 0.62 | 3.3±0.05 | 1.0 | 0.75 | 9.0±0.20 | 13.3 |
| 3G 2.5mm² | 49X0.254mm | 0.9 | 0.71 | 3.95±0.05 | 1.1 | 0.84 | 11.0±0.20 | 7.98 |
| 4G0.75mm² | 24X0.20mm | 0.6 | 0.44 | 2.4±0.05 | 0.9 | 0.67 | 7.8±0.20 | 26 |
| 4G 1.0mm² | 32X0.20mm | 0.6 | 0.44 | 2.6±0.05 | 0.9 | 0.67 | 8.3±0.20 | 19.5 |
| 4G 1.5mm² | 48X0.20mm | 0.8 | 0.62 | 3.3±0.05 | 1.1 | 0.84 | 0.4±0.20 | 13.3 |
| 4G 2.5mm² | 49X0.254mm | 0.9 | 0.71 | 3.95±0.05 | 1.2 | 0.92 | 12.3±0.20 | 7.98 |
(SAA Certificated, approval according to AS/NZS 60245.4 or UCIEE Certificated, approval according to IEC 60245.4)
| No of cores x nominal cross sectional area | Copper wire number x diameter | Insulation thickness | Insulation on diam (mm) | Sheath thickness (mm) | Completed Diam(mm) | Max conductor resistance(Ω/km) | ||
| The average | The minimum | The average | The minimum | |||||
| 2×0.75mm² | 24X0.20mm | 0.6 | 0.44 | 2.4±0.05 | 0.8 | 0.58 | 6.4±0.20 | 26 |
| 2×1.0mm² | 32X0.20mm | 0.6 | 0.44 | 2.6±0.05 | 0.9 | 0.67 | 7.0±0.20 | 19.5 |
| 2×2.5mm² | 48X0.20mm | 0.8 | 0.62 | 3.3±0.05 | 1.0 | 0.75 | 8.4±0.20 | 13.3 |
| 3G0,75mm² | 49X0.254mm | 0.9 | 0.71 | 3.95±0.05 | 1.1 | 0.84 | 10.2±0.20 | 7.98 |
| 3G0,75mm² | 24X0.20mm | 0.6 | 0.44 | 2.4±0.05 | 0.9 | 0.67 | 7.0±0.20 | 26 |
| 3G0,75mm² | 32X0.20mm | 0.6 | 0.44 | 2.6±0.05 | 0.9 | 0.67 | 7.3±0.20 | 19.5 |
| 3G 1.5mm² | 48X0.20mm | 0.8 | 0.62 | 3.3±0.05 | 1.0 | 0.75 | 9.0±0.20 | 13.3 |
Related products
-
Rubber Cable
SJ SJO SJOO SJOW SJOOW Cable
-
Rubber Cable
HPN Cable
-
Rubber Cable
H07RN-F Cable
-
Rubber Cable
H05RNH2-F cable