H05RN-F Cable

  • High flexibility, easy to handle, bend, and install in tight spaces
  • Rated at 300V/500V
  • VDE approved, ROHS & REACH complant
  • EPR insulated, CPE sheathed

     

H05RN-F cable is a resilient type of rubber-insulated flexible cable, which follow the DIN EN50525-2-21 standard. The rated voltage of the H05RN-F cable is 300/500v. It features a robust construction with fine-stranded copper conductors insulated by ethylene propylene rubber (EPR), ensuring excellent electrical conductivity and insulation properties. The  harmonized cable is available in various core configurations, including single-core and multi-core options, to accommodate different voltage and current requirements. And its nominal cross-section are provided in 0.75mm² and 1.0mm², 1.5mm².

The rubber sheathing of the H05RN-F cable provides additional protection against moisture, oil, chemicals, and UV radiation, making it suitable for both indoor and outdoor use, whether in moist or arid environments. These cable are frequently utilized in conjunction with gardening equipment or workshop machinery. Moreover, it serves as a reliable option for permanent fixtures within furniture, ornamental facades, wall dividers, and prefabricated structural components.

Certification VDE, SAA
Operating temperature -35℃+60℃
Rated voltage 300V/500V
Conductor Bare or tinned stranded copper conductor
Insulation material EPR
Sheath material CPE

H05RN-F Cable Construction

(VDE Certificated, Approval according to DIN EN 50525-2-82 )
No of cores x nominal cross sectional area Copper wire number x diameter Insulation thickness Insulation on  diam (mm) Sheath thickness (mm) Completed Diam(mm) Max conductor resistance(Ω/km)
The average The minimum The average The minimum
1×0.75mm² 24X0.20mm 0.8 0.62 2.8±0.05 0.8 0.58 4.5±0.15 26
1×1.0mm² 32X0.20mm 0.8 0.62 2.9±0.05 0.8 0.58 4.7±0.15 19.5
1×1.5mm² 48X0.20mm 0.8 0.62 3.2±0.05 0.8 0.58 5.0±0.15 13.3
(VDE Certificated, Approval according to DIN EN 50525-2-21 )
No of cores x nominal cross sectional area Copper wire number x diameter Insulation thickness Insulation on  diam (mm) Sheath thickness (mm) Completed Diam(mm) Max conductor resistance(Ω/km)
The average The minimum The average The minimum
2×0.75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.8 0.58 6.4±0.20 26
2×1.0mm² 32X0.20mm or 57×0.15mm 0.6 0.44 2.6±0.05 0.9 0.67 7.0±0.20 19.5
3G0.75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.9 0.67 7.0±0.20 26
3G 1.0mm² 32×0.20mm 0.6 0.44 2.6±0.05 0.9 0.67 7.3±0.20 19.5
(SAA Certificated, Approval according to AS/NZS 60245.4)
No of cores x nominal cross sectional area Copper wire number x diameter Insulation thickness Insulation on  diam (mm) Sheath thickness (mm) Completed Diam(mm) Max conductor resistance(Ω/km)
The average The minimum The average The minimum
2×0.75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.8 0.58 6.4±0.20 26
2×1.0mm² 32X0.20mm 0.6 0.44 2.6±0.05 0.9 0.67 7.0±0.20 19.5
3G0.75mm² 24X0.20mm 0.6 0.44 2.4±0.05 0.9 0.67 7.0±0.20 26
3G 1.0mm² 32×0.20 0.6 0.44 2.6±0.05 0.9 0.67 7.3±0.20 19.5